We recommend
New
2 MPX High-Speed Dome IP Camera with Face Recognition, License Plate Recognition and Object Tracking
NVIP-2SD-4550/18/F
Function alarming the user in case of fire in the camera's field of view. Reaction to an alarm event can be an alarm output activation, a light alarm, an audio alarm, an e-mail or sending an event to the DVR.
Thermo Dual Vision is a feature available on dual cameras. It allows the thermal image to be overlayed on the video image which significantly improves the detail of the recorded image.
Camera classify and is able to autotrack selected type of object:
- person
- bike/motorbike
- car
Tracking can be triggered by zone entrance or line crossing of chosen object type
INGENIUS PLUS - a new generation of intelligent image analysis based on Deep Learning. The algorithm used allows the camera to recognize the shape of a human, a car and bike/motorcycle, even as small as 1% of the stage. The efficiency of the analysis methods used allows simultaneous classify and monitoring of up to 32 objects of different types.
Image analysis based on Deep Learning enabling the counting of objects with recognized shapes (human, a car and bike/motorcycle) that crossed the virtual line. The camera can display the number of these objects in the image.
The function allows to trigger a local alarm, send an e-mail, activate the relay, or send a push notification to the mobile application after the object (human, car or bike/motorbike has crossed the previously defined detection zone.
Application example:
- perimeter protection of the object
- protection of strategically important objects
The function allows to trigger a local alarm, send an e-mail, activate the relay, or send a push notification to the mobile application after the object (human, car or bike/motorbike has crossed the previously defined line (maximum 4 lines per one camera).
Application example:
- perimeter protection of the object
The thermal image is created based on thermal radiation emitted by objects. Thanks to this, thermal imaging cameras allow effective observation even in total darkness and during adverse weather conditions such as fog, where standard cameras, even those equipped with an IR illuminator, do not work. In addition, thermal imaging cameras have been equipped with image analysis functions thanks to which the detection efficiency of objects is very high.
The camera uses HTML5 standard (programming language) to display the image in the browser.
This allows to configure and display stream from camera not only from Internet Explorer, but in all popular browsers, like Opera, Firefox, Edge or Chrome. Thanks to HTML5, the user can safely and conveniently connect to the camera, the high performance of HTML5 protocol allows to high definition video display without lag and with moderate consumption of computer resources.
Novus Management System VSS software is an advanced platform for managing video monitoring system. Novus Management System VSS can combine different standards of CCTV: Analog, AHD, IP, and at the same time is a software with a high degree of flexibility, finding its application in both small and large and distributed installations
The video encoding standard, which is the successor to the H.264 standard, which allows to save up to 35% of the bandwidth.
This function allows to trigger an alarm after detecting exceeding a set temperature threshold in a specific zone, point or on a defined line. Possible alarm responses are: local alarm, alarm in Novus Management System VSS, e-mail, save to FTP, save to SD card, activation of the alarm output.
This function allows the temperature of objects to be measured at a selected point/area of the observed scene.
With the "Fire Detection" feature, the camera can detect fires in their early stages, before flames or smoke even appear. By analyzing the image, the camera detects high-temperature point sources of heat, which allows to quickly generate an alarm. This feature is particularly useful in places with a high risk of fire, such as warehouses, factories and public facilities, enabling quick response and minimizing damage.
Image - Thermal Module | |
---|---|
Image Sensor | Uncooled FPA Microbolometer |
Number of Effective Pixels | 400 (H) x 300 (V) |
Pixel Size | 17 µm |
Spectral Range | 8 - 14 µm |
Thermal Sensitivity | 40 mK |
Thermovision Modes | White Hot, Black Hot, Rainbow, Ironbow, HSV, Autumn, Bone, Cool, Copper, Fire Hot, Pink, Spring, Summer, Winter, Jet, Flame, Rosebengal |
Detection Temperature | -20°C ~ 150°C |
Digital Noise Reduction (DNR) | 2D, 3D |
Lens - Thermal Module | |
Lens Type | fixed focal length, f=35 mm/F1.0, with manual focus |
Object Detection Range | 1029m - human , 3137m - vehicle , 1029m - fire |
Object Recognition Range | 257m - human , 789m - vehicle |
Image | |
Image Sensor | 4 MPX CMOS sensor 1/2.8” SONY |
Number of Effective Pixels | 2592 (H) x 1520 (V) |
Min. Illumination | 0.01 lx/F1.2 - color mode, 0.001 lx/F1.2 - B/W mode |
Electronic Shutter | auto: 1/5 s ~ 1/20000 s |
Digital Slow Shutter (DSS) | up to 1/5 s |
Wide Dynamic Range (WDR) | yes (double scan sensor) |
Digital Image Stabilization (DIS) | yes |
Digital Noise Reduction (DNR) | 3D |
Defog Function (F-DNR) | yes |
Highlight Compensation (HLC) | yes |
Back Light Compensation (BLC) | yes |
Lens | |
Optical Zoom | 30x |
Lens Type | motorized, auto-iris function, f=5.3 ~ 159 mm/F1.6 ~ F4.3 |
Auto-focus | zoom trigger, manual trigger |
Day/Night | |
Switching Type | mechanical IR cut filter |
Switching Mode | auto, time |
Switching Level Adjustment | yes |
Switching Delay | 0 ~ 180 s |
Network | |
Stream Resolution | 2560 x 1440 (QHD), 2592 x 1520, 2304 x 1296, 1920 x 1080 (Full HD), 1280 x 720 (HD), 720 x 576 (D1), 640 x 480 (VGA), 352 x 288 (CIF), 320 x 240 (QVGA) for thermal module: 704 x 576, 352 x 240 |
Frame Rate | 30 fps for each resolution |
Multistreaming Mode | number of streams: 3 (main stream, sub stream, third stream) |
Video/Audio Compression | H.264, H.265, MJPEG/G.711, RAW_PCM |
Number of Simultaneous Connections | max. 10 |
Network Protocols Support | HTTP, TCP/IP, IPv4/v6, UDP, DHCP, DNS, RTSP, RTP, IEEE 802.1X, PPPoE, SMTP, RTCP, HTML5 |
Camera Configuration | from Edge, Firefox, Chrome browser languages: Polish, English, and others |
Compatible Software | NOVUS MANAGEMENT SYSTEM VSS |
PTZ | |
Preset Commands | 400 |
Tours | 12 (up to 32 presets per tour) |
Auto-Scans | 8 |
Patterns | 6 |
Tilt/Pan Range | -90° ~ 90°/360° (continuous) |
Pan/Tilt Speed | up to 60°/s (proportional to zoom) |
Preset Speed | up to 60°/s |
Video Analytics | |
Functions | line cross, zone entrance, zone exit, double line cross, loiter, converse, objects distinguishing, people counting for thermal module: fire detection, temperature measurement, fire source detection, smoke detection |
Other functions | |
Temperature Measurement | yes - for thermal module |
Temperature Alarm | yes - for thermal module |
Temperature Measurement Zones | 20 - for thermal module polygon, line, point |
Temperature Measurement Accuracy | +-2°C / +-2% |
Privacy Zones | 4 video mask type: single color |
Motion Detection | yes |
Region of interest (ROI) | 8 |
Audio Detection | yes |
Image Processing | Defective Pixel Correction (DPC), mirror effect, vertical flip, horizontal flip |
System Reaction to Alarm Events | e-mail with attachment, saving file on FTP server, alarm output activation, playback of the audio message |
Restoring default settings | via web browser |
Interfaces | |
Video Output | BNC, 1.0 Vp-p, 75 Ohm |
Audio Input/Output | 2 x Jack (3.5 mm)/2 x Jack (3.5 mm) |
Alarm Input/Output | 9 (NO/NC)/4 |
Network Interface | 1 x Ethernet - RJ-45 interface, 10/100 Mbit/s |
Installation parameters | |
Dimensions (mm) | with bracket: 419 (W) x 316 (H) x 282 (L) 4 m long connection cables |
Weight | 16.5 kg |
Degree of Protection | IP 66 (details in the user’s manual) |
Enclosure | aluminium, white, Enclosure type: 8S |
Power Supply | 36 VDC (power supply included) |
Power Consumption | 80 W |
Operating Temperature | -40°C ~ 60°C |
Humidity | max. 90%, relative (non-condensing) |
Built-in Heater/Fan | yes/yes |